Testing and Calibration of Fixed Gas Detector Heads
Introduction
In order to ensure the safe and accurate operation of Fixed Gas Detectors, they need to be periodically calibrated against reference test gases that are traceable to National Physical Laboratory standards. The recommended calibration period for Status Scientific Controls gas detectors is six months although the frequency may need to be increased where continual exposure to the target gases is experienced.
Between calibrations it is also recommended that the response of the detector is checked using an appropriate test gas cylinder. These cylinders are available in 'large aerosol' form and may be supplied individually or as part of a Field Calibration Kit.
Status Scientific Controls offers a range of support equipment, including compressed gases, for the customer to carry out both calibration and response testing of Fixed Gas Detectors.

110 Litre Test Gas Large Aerosol Cylinder

110 Litre Cylinder Flow Regulator
Order Codes - Calibration Equipment
| Stock No. | Description |
|---|---|
| SS334 | Metal 'Flow Through' Sampling Adaptor - 1/8" BSP - for permanent installations (excludes tubing). |
| SS335 | PTFE Sampling Adaptor & 1 Metre PTFE Tubing (use for absorbent gases). For Fixed Gas Detector Heads. |
| SS336 | Metal Sampling Adaptor & 1 Metre Tubing. For Fixed Gas Detector Heads. |
| SS337 | PTFE Sampling Kit - Comprises Stainless Steel Regulator, PTFE Sampling Adaptor & 1 Metre PTFE Tubing (use for absorbent gases). For Fixed Gas Detector Heads. |
| SS338 | Metal Sampling Kit - Comprises Regulator, Metal Sampling Adaptor & 1 Metre Tubing. For Fixed Gas Detector Heads. |
Order Codes - Test Gases in Large Aerosol Form (110 Litres of Gas)
| Stock No. | Description |
|---|---|
| SS220 | Methane 25% LEL, balance air |
| SS221 | Methane 50% LEL, balance air |
| SS222 | Propane 20% LEL, balance ai |
| SS226 | Carbon Monoxide 50ppm, balance air |
| SS227 | Carbon Monoxide 200ppm, balance air |
| SS229 | Hydrogen Sulphide 25ppm, balance Nitrogen |
| SS230 | Sulphur Dioxide 10ppm, balance Nitrogen |
| SS231 | Compressed Air 20.9% |
| SS232 | Propane 50% LEL, balance air |
| SS233 | Carbon Dioxide 2%, balance air |
| SS234 | Methane 99.9% volume |
| SS235 | Methane 30% LEL, balance air |
| SS236 | Carbon Monoxide 65ppm, Methane 1.5% volume, Hydrogen Sulphide 25ppm, Oxygen 18.5%, balance Nitrogen |
| SS237 | Hydrogen Sulphide 80ppm, balance Nitrogen |
| SS238 | Hydrogen Sulphide 30ppm, Methane 2.5% volume, Oxygen 18.5%, balance Nitrogen |
| SS239 | Chlorine 10ppm, balance Nitrogen |
| SS240 | Carbon Monoxide 65ppm, Methane 1.5% volume, Oxygen 18.5%, balance Nitrogen |
| SS241 | Hydrogen 1% volume, balance air |
| SS242 | Nitrogen Dioxide 10ppm, balance air |
| SS243 | Hydrogen Chloride 10ppm, balance Nitrogen |
| SS244 | Hydrogen Cyanide 10ppm, balance Nitrogen |