Gas Detector Control Panel - 1 To 16 Channel Type MCU4 - For Use With Remote Fixed Gas Detector Heads Or Other Environmental Sensors. 

Features 

Can be used with the full range of Status Scientific Controls fixed gas detector heads - certified types require use of an integral safety barrier. 
Graphical displays with backlight with the ability to display trend data in graphical form. 
Menu selection via push buttons on front panel. 
Integral audible alarm. 
Integral sealed lead-acid standby battery. 
Integral safety barrier option for each channel. 
3 control relays per channel providing LOW, MEDIUM & HIGH alarm level contact outputs for each channel. 
Common alarm relay contact outputs providing LOW, MEDIUM & HIGH alarms plus FAULT conditions on any channel to power external equipment. 
Lockable door. 
Water and dust proof to IP66. 
Compatible with industry standard gas detectors and other sensors. 
 
Description 
 
Although primarily designed for use with the Status Scientific Controls range of fixed gas detectors, the MCU4 Monitoring and Control Unit provides facilities to accept up to 8 individual inputs from various types of monitoring instruments or transducers. A graphical display is provided to show the status of each channel, display graphs and enable configuration of the unit (e.g. set the alarm levels, program the output relay voting etc.). The unit can be programmed on-site by the user using the password protected configuration facility. Each monitoring channel provides relay contact outputs together with 4 to 20mA and voltage outputs. Data logging of each channel is provided as standard. 
 
Internal Safety Barrier 
For applications where the gas detector head (or other sensor type) is sited in a potentially explosive atmosphere, a safety barrier must be fitted in order to limit the maximum voltage and current under a fault condition (e.g. short circuit) such that an incendive spark cannot be created. Where suitable*, the internal safety barrier shown above may be fitted within the control unit. This can either be fitted at the time of manufacture (where requested) or at a later time if the system is extended by the installation of additional detectors. 
 
*Note that some installations may neccessitate the use of external barriers sited at the safe area/hazardous area interface - see the accessories page. 
Stock No. SS310 - MCU4 16- Channel Control Unit 
Stock No. SS323 - MCU4 2- Channel Control Unit Enclosure Only 
Stock No. SS503- Internal Safety Barrier (one per channel) 
For Quality Gas Detection at  
 
Competitive Prices Contact 
 
sales@status-scientific.com 
 
International - +44 (0) 1623 651381 
For Quality Gas Detection at Competitive Prices 
 
Contact 
 
sales@status-scientific.com 
 
International - +44 (0) 1623 651381