Intrinsically Safe Ammonia Fixed Gas Detector FGD3 Series Using Electrochemical Gas Sensor Technology

Features
Standard ranges 0-100ppm or 0-1000ppm Ammonia NH3.
Suitable for use in Zones 1 and 2 hazardous areas.
Two wire connection.
8 to 24 volt dc operation.
Industry standard 4 to 20mA output.
Digital display.
Single operator calibration.
Other FGD3 Gas Types Available - | Carbon Dioxide | Carbon Monoxide | Chlorine | Flammable (Catalytic) | Flammable (Infrared) | Hydrogen | Hydrogen Chloride | Hydrogen Cyanide | Hydrogen Sulphide | Methane | Nitric Oxide | Nitrogen Dioxide | Oxygen | Sulphur Dioxide |
Hazardous Area Certificate No.
BAS 01ATEX2300
II 2 G Ex ia IIC T4 Gb (-20 deg. C ≤Ta≤ +60 deg. C)
Description
The FGD 3 Ammonia Gas Detector uses electrochemical sensor technology to detect the level of Ammonia in the atmosphere over the ranges 0 - 100ppm or 0 - 1000ppm. The detectors use the industry standard 4-20mA current loop both to power the detector and to convey the gas levels detected to a separate control unit such as the Status Scientific Controls MCU Series. This means that under zero gas conditions 4mA is drawn from the supply, and under full scale gas conditions 20mA is drawn from the supply. The current varies linearly for gas levels between zero and full scale. The detector head uses a two-wire connection.
Stock No. |
Description |
SS406-100 |
FGD3 Ammonia Gas Detector - (4-20mA Output) - Range 0-100ppm NH3 |
SS406-1000 |
FGD3 Ammonia Gas Detector - (4-20mA Output) - Range 0-1000ppm NH3 |